Laboratory evidence
Published results by batch. They apply only to the listed sample and date; unlisted testing is not evidence of safety.
Heavy Metals
4/4 passed
- Arsenic (As)0.13%of limit0.001 ppm · Limit: < 0.75 ppm
This result applies only to the reported sample and test date. See the original report for the laboratory method.
Within limitBatch historyEquivalent results are converted to one unit across batches. Solid markers are measured amounts. Hollow markers are reported bounds, not exact amounts. Less-than signs are preserved; not detected is not a measured zero. Report limits can differ between batches.
Apr 2026 · 10026: 0.005 ppm
Oct 2026 · 26426: 0.001 ppm
5 ppbApr 2026 · 100261 ppbOct 2026 · 26426 - Cadmium (Cd)<0.14%of report limit< 0.001 ppm · Limit: < 0.75 ppm
The lab reported a bound, not an exact amount. A hollow marker, when shown, marks the upper bound; the amount may be anywhere below it. This is not a measured zero.
Within limitBatch historyEquivalent results are converted to one unit across batches. Solid markers are measured amounts. Hollow markers are reported bounds, not exact amounts. Less-than signs are preserved; not detected is not a measured zero. Report limits can differ between batches.
Apr 2026 · 10026: < 0.001 ppm
Oct 2026 · 26426: < 0.001 ppm
<1 ppbApr 2026 · 10026<1 ppbOct 2026 · 26426 - Lead (Pb)1.07%of limit0.016 ppm · Limit: < 1.5 ppm
This result applies only to the reported sample and test date. See the original report for the laboratory method.
Within limitBatch historyEquivalent results are converted to one unit across batches. Solid markers are measured amounts. Hollow markers are reported bounds, not exact amounts. Less-than signs are preserved; not detected is not a measured zero. Report limits can differ between batches.
Apr 2026 · 10026: 0.006 ppm
Oct 2026 · 26426: 0.016 ppm
6 ppbApr 2026 · 1002616 ppbOct 2026 · 26426 - Mercury (Hg)0.2%of limit0.001 ppm · Limit: < 0.5 ppm
This result applies only to the reported sample and test date. See the original report for the laboratory method.
Within limitBatch historyEquivalent results are converted to one unit across batches. Solid markers are measured amounts. Hollow markers are reported bounds, not exact amounts. Less-than signs are preserved; not detected is not a measured zero. Report limits can differ between batches.
Apr 2026 · 10026: 0.001 ppm
Oct 2026 · 26426: 0.001 ppm
1 ppbApr 2026 · 100261 ppbOct 2026 · 26426
Microbials
7/7 passed
Checks for bacteria, yeast and mold.
- ColiformsNot detectedLimit: ≤ 1,000 cfu's/g
Not detected is not a measured zero. See the original report for detection and reporting details. Not detected is not a measured zero. See the original report for the method and detection information. Not detected in both lots
Not detected - E. coliNot detectedRequirement: Absent
Not detected is not a measured zero. See the original report for detection and reporting details. Not detected is not a measured zero. See the original report for the method and detection information. Not detected in both lots
Not detected - MoldNot detectedLimit: ≤ 10,000 cfu's/g
Not detected is not a measured zero. See the original report for detection and reporting details. Not detected is not a measured zero. See the original report for the method and detection information.
Not detected - SalmonellaNot detectedRequirement: Absent
Not detected is not a measured zero. See the original report for detection and reporting details. Not detected is not a measured zero. See the original report for the method and detection information. Not detected in both lots
Not detected - Staphylococcus aureusNot detectedRequirement: Absent
Not detected is not a measured zero. See the original report for detection and reporting details. Not detected is not a measured zero. See the original report for the method and detection information. Not detected in both lots
Not detected - Total Plate Count1%of limit1,000 cfu's/g · Limit: < 100,000 cfu's/g
This result applies only to the reported sample and test date. See the original report for the laboratory method.
Within limitBatch historyEquivalent results are converted to one unit across batches. Solid markers are measured amounts. Hollow markers are reported bounds, not exact amounts. Less-than signs are preserved; not detected is not a measured zero. Report limits can differ between batches.
Apr 2026 · 10026: None Detected
Oct 2026 · 26426: 1,000 cfu's/g
Not detectedApr 2026 · 100261000 cfu's/gOct 2026 · 26426 - YeastNot detectedLimit: ≤ 10,000 cfu's/g
Not detected is not a measured zero. See the original report for detection and reporting details. Not detected is not a measured zero. See the original report for the method and detection information.
Not detected
Glyphosate
<0.4 %
- Glyphosate (HPLC)<0.4 %Limit: ≤ 0.4 %
The lab reported a bound, not an exact amount. A hollow marker, when shown, marks the upper bound; the amount may be anywhere below it. This is not a measured zero. The comparison uses the listed report limit; the lab did not provide a pass/fail verdict.
Reported